Control Panel Elentek Smart Pro 220V

155.00  excl. VAT

In stock

Born from the need to combine in a single product the functions of panels for clean water (emptying, filling, pressurization, etc) and sewage pump panels (emptying and sewage water) and to offer always more function, safety, and control, Smart Pro raises the standard without extra cost!

Compare

Frequently Bought Together

Born from the need to combine in a single product the functions of panels for clean water (emptying, filling, pressurization, etc) and sewage pump panels (emptying and sewage water) and to offer always more function, safety, and control, Smart Pro raises the standard without extra cost!

The control panels Smart Pro are made in an original Elentek thermoplastic ABS design box, watertight, self-extinguishing, IP55.

Each panel has LED lights signaling voltage presence, thermal protection and motor running, a main switch interlocking door, pushbuttons for manual or automatic operation, level relay for probes volt free alarm contacts.

The users and external controls such as float switches and pressure switches are to be connected to the terminals of the main electronic board.

GENERAL FEATURES

  • Power supply 1phase 100-240Vac 50/60Hz;
  • Input for 3 single-pole probes (COM-MIN-MAX);
  • Input G.A. normally open for alarm activation;
  • Push-buttons for selecting operation
  • AUTOMATIC-0-MANUAL(temporary);
  • DIP-SWITCH selectors for:
    • enabling level alarm from probes;
    • thermal cut-out activation delay 5/10 seconds;
    • alarm output settings;
    • alarm reset enable from motor clicson;
    • filling/emptying mode;
    • enabling start/stop float function;
    • delay of electronic board activation on power mains return.
  • Green led: power ON / failure or incorrect phase sequence;
  • Red led: level alarm from probes or GA input;
  • Electronic control of max current due to overload, with assisted calibration;
  • Electronic control of minimum current due to dry run, with assisted calibration;
  • Automatic reset due to minimum current alarm;
  • Timer for delay of motor enabling on power mains return;
  • Protection of auxiliary circuits and motor with fuses;
  • Cumulative alarm output with voltage-free contacts (COM-NO-NC resistive load – 5A / 250V);
  • Cumulative alarm output, live (12Vcc / 100mA);
  • Door lock general disconnect switch;
  • Provision for run capacitors, single phase version (not included);
  • Box in ABS, IP55;
  • Ambient temperature: -5/+40 °C;
  • Relative humidity 50% at 40 °C (condensate free).