A wide range of instruments for detecting, monitoring, and remediation of pollutions by hydrocarbons in water and soil: oil/water interface meters, ATEX borehole pumps, ATEX self-priming pumps, ATEX pneumatic pumps, ATEX submersible pumps, and equipment for passive hydrocarbon recovery
-
ATEX Oil/Water Interface Meter Heron H.OIL
- Certified intrinsically safe to ATEx, IECEx, CSA, and UL standards
- Detects floating product (LNAPL), sinking product (DNAPL) and water
- Measures extremely thin spots of liquid (1mm (1/200’))
- Earthing
- Electronic Module (IP65) – Automatical turning off after 10 minutes, can be easily removed if cleaning and repairing are needed
- Probe (IP68) – stands against high pressure, 19mm (3/4”), easy to replace
- Steel Tape – strong and reliable with Kynar covering, long-lasting markings in both scales
- Padded Carry Case – for protection
- Hanger – for supporting the tool on the top
- Handle – comfortable and solid handle on the frame
- Winding Handle – makes it easy to rewind with gloves on
Price On RequestATEX Oil/Water Interface Meter Heron H.OIL
Price On Request -
ATEX Oil/Water Interface Meter Heron Sm.OIL
- Certified intrinsically safe to ATEx, IECEx, CSA, and UL standards
- Detects floating product (LNAPL), sinking product (DNAPL) and water
- Measures extremely thin spots of liquid (1mm (1/200’))
- Earthing
- Electronic Module (IP65) – Automatical turning off after 10 minutes, can be easily removed if cleaning and repairing are needed
- Probe (IP68) – stands against high pressure, 19mm (3/4”), easy to replace
- Steel Tape – strong and reliable with Kynar covering, long-lasting markings in both scales
- Padded Carry Case – for protection
- Hanger – for supporting the tool on the top
- Handle – comfortable and solid handle on the frame
- Winding Handle – makes it easy to rewind with gloves on
Price On RequestATEX Oil/Water Interface Meter Heron Sm.OIL
Price On Request -
4″ ATEX VP4 Bottom Loading Pump
- Pump length: 1005 mm
- Liquid inlet position: Bottom
- Max flow rate: >2880 l/hr
- Pump discharge cycle: 0.9 – 1.1 litres
- Pump outside Diameter: 90 mm
- Min operating borehole diameter: 100 mm
- Max working depth: 130 m
- Pump weight: 7.5kg
Price On Request4″ ATEX VP4 Bottom Loading Pump
Price On Request -
3″ ATEX VP3 Bottom Loading Pump
- Pump length: 1120 mm
- Liquid inlet position: Bottom
- Max flow rate: >1200 l/hr
- Pump discharge cycle: 0.6 litres
- Pump outside Diameter: 70 mm
- Min operating borehole diameter: 80 mm
- Max working depth: 130 m
- Pump weight: 5 kg
Price On Request3″ ATEX VP3 Bottom Loading Pump
Price On Request -
2″ ATEX VP2 Bottom Loading Pump
- Pump length: 945 mm
- Liquid inlet position: Bottom
- Max flow rate: >475 l/hr
- Pump discharge cycle: 0.33 litres
- Pump outside Diameter: 44 mm
- Min operating borehole diameter: 50 mm
- Max working depth: 130 m
- Pump weight: 1.5 kg
Price On Request2″ ATEX VP2 Bottom Loading Pump
Price On Request -
4″ ATEX VP4 Top Loading Pump
- Pump length: 1100 mm
- Liquid inlet position: Top
- Max flow rate: >2100 l/hr
- Pump discharge cycle: 0.9 – 1.1 litres
- Pump outside Diameter: 90 mm
- Min operating borehole diameter: 100 mm
- Max working depth: 130 m
- Pump weight: 7.5 kg
Price On Request4″ ATEX VP4 Top Loading Pump
Price On Request -
3″ ATEX VP3 Top Loading Pump
- Pump length: 1190 mm
- Liquid inlet position: Top
- Max flow rate: >1000 l/hr
- Pump discharge cycle: 0.6 litres
- Pump outside Diameter: 70 mm
- Min operating borehole diameter: 80 mm
- Max working depth: 130 m
- Pump weight: 5.5 kg
Price On Request3″ ATEX VP3 Top Loading Pump
Price On Request -
2″ ATEX VP2 Top Loading Pump
- Pump length: 995 mm
- Liquid inlet position: Top
- Max flow rate: >400 l/hr
- Pump discharge cycle: 0.3 liters
- Pump outside Diameter: 44 mm
- Min operating borehole diameter: 50 mm
- Max working depth: 130 m
- Pump weight: 2 kg
Price On Request2″ ATEX VP2 Top Loading Pump
Price On Request -
4″ ATEX VP4 Bottom Loader Low Draw Down
- Pump length: 580 mm
- Liquid inlet position: Bottom
- Max flow rate: >1200 l/hr
- Pump discharge cycle: 0.5 litres
- Pump outside Diameter: 90 mm
- Min operating borehole diameter: 100 mm
- Max working depth: 130 m
- Pump weight: 5.5kg
Price On Request4″ ATEX VP4 Bottom Loader Low Draw Down
Price On Request -
4″ ATEX VP4 Top Loader Low Draw Down
- Pump length: 750 mm
- Liquid inlet position: Top
- Max flow rate: >1200 l/hr
- Pump discharge cycle: 0.4 litres
- Pump outside Diameter: 90 mm
- Min operating borehole diameter: 100 mm
- Max working depth: 130 m
- Pump weight: 6 kg
Price On Request4″ ATEX VP4 Top Loader Low Draw Down
Price On Request -
3″ ATEX VP3 Bottom Loader Low Draw Down
- Pump length: 670 mm
- Liquid inlet position: Bottom
- Max flow rate: >900 l/hr
- Pump discharge cycle: 0.5 litres
- Pump outside Diameter: 70 mm
- Min operating borehole diameter: 80 mm
- Max working depth: 130 m
- Pump weight: 3 kg
Price On Request3″ ATEX VP3 Bottom Loader Low Draw Down
Price On Request -
3″ ATEX VP3 Top Loader Low Draw Down
- Pump length: 830 mm
- Liquid inlet position: Top
- Max flow rate: >870 l/hr
- Pump discharge cycle: 0.5 litres
- Pump outside Diameter: 70 mm
- Min operating borehole diameter: 80 mm
- Max working depth: 130 m
- Pump weight: 3.5 kg
Price On Request3″ ATEX VP3 Top Loader Low Draw Down
Price On Request