A wide range of instruments for detecting, monitoring, and remediation of pollutions by hydrocarbons in water and soil: oil/water interface meters, ATEX borehole pumps, ATEX self-priming pumps, ATEX pneumatic pumps, ATEX submersible pumps, and equipment for passive hydrocarbon recovery
-
4″ ATEX VP4 Top Loader Low Draw Down
- Pump length: 750 mm
- Liquid inlet position: Top
- Max flow rate: >1200 l/hr
- Pump discharge cycle: 0.4 litres
- Pump outside Diameter: 90 mm
- Min operating borehole diameter: 100 mm
- Max working depth: 130 m
- Pump weight: 6 kg
Price On Request4″ ATEX VP4 Top Loader Low Draw Down
Price On Request -
4″ ATEX VP4 Bottom Loader Low Draw Down
- Pump length: 580 mm
- Liquid inlet position: Bottom
- Max flow rate: >1200 l/hr
- Pump discharge cycle: 0.5 litres
- Pump outside Diameter: 90 mm
- Min operating borehole diameter: 100 mm
- Max working depth: 130 m
- Pump weight: 5.5kg
Price On Request4″ ATEX VP4 Bottom Loader Low Draw Down
Price On Request -
2″ ATEX VP2 Top Loading Pump
- Pump length: 995 mm
- Liquid inlet position: Top
- Max flow rate: >400 l/hr
- Pump discharge cycle: 0.3 liters
- Pump outside Diameter: 44 mm
- Min operating borehole diameter: 50 mm
- Max working depth: 130 m
- Pump weight: 2 kg
Price On Request2″ ATEX VP2 Top Loading Pump
Price On Request -
3″ ATEX VP3 Top Loading Pump
- Pump length: 1190 mm
- Liquid inlet position: Top
- Max flow rate: >1000 l/hr
- Pump discharge cycle: 0.6 litres
- Pump outside Diameter: 70 mm
- Min operating borehole diameter: 80 mm
- Max working depth: 130 m
- Pump weight: 5.5 kg
Price On Request3″ ATEX VP3 Top Loading Pump
Price On Request -
4″ ATEX VP4 Top Loading Pump
- Pump length: 1100 mm
- Liquid inlet position: Top
- Max flow rate: >2100 l/hr
- Pump discharge cycle: 0.9 – 1.1 litres
- Pump outside Diameter: 90 mm
- Min operating borehole diameter: 100 mm
- Max working depth: 130 m
- Pump weight: 7.5 kg
Price On Request4″ ATEX VP4 Top Loading Pump
Price On Request -
2″ ATEX VP2 Bottom Loading Pump
- Pump length: 945 mm
- Liquid inlet position: Bottom
- Max flow rate: >475 l/hr
- Pump discharge cycle: 0.33 litres
- Pump outside Diameter: 44 mm
- Min operating borehole diameter: 50 mm
- Max working depth: 130 m
- Pump weight: 1.5 kg
Price On Request2″ ATEX VP2 Bottom Loading Pump
Price On Request -
3″ ATEX VP3 Bottom Loading Pump
- Pump length: 1120 mm
- Liquid inlet position: Bottom
- Max flow rate: >1200 l/hr
- Pump discharge cycle: 0.6 litres
- Pump outside Diameter: 70 mm
- Min operating borehole diameter: 80 mm
- Max working depth: 130 m
- Pump weight: 5 kg
Price On Request3″ ATEX VP3 Bottom Loading Pump
Price On Request -
4″ ATEX VP4 Bottom Loading Pump
- Pump length: 1005 mm
- Liquid inlet position: Bottom
- Max flow rate: >2880 l/hr
- Pump discharge cycle: 0.9 – 1.1 litres
- Pump outside Diameter: 90 mm
- Min operating borehole diameter: 100 mm
- Max working depth: 130 m
- Pump weight: 7.5kg
Price On Request4″ ATEX VP4 Bottom Loading Pump
Price On Request -
4″ ATEX Pump ID BETA EX 13 kW 2.2
Pumping of liquids and extraction of leachate in landfill, drainage of fluids contaminated by hydrocarbons and groundwater. The ATEX pumps in conformity with 2014/34/UE Directive can be installed in potentially explosive atmospheres according to the marking explained hereafter.
Price On Request4″ ATEX Pump ID BETA EX 13 kW 2.2
Price On Request -
4″ ATEX Pump ID BETA EX 9 kW 1.5
Pumping of liquids and extraction of leachate in landfill, drainage of fluids contaminated by hydrocarbons and groundwater. The ATEX pumps in conformity with 2014/34/UE Directive can be installed in potentially explosive atmospheres according to the marking explained hereafter.
Price On Request4″ ATEX Pump ID BETA EX 9 kW 1.5
Price On Request -
4″ ATEX Pump ID BETA EX 6 kW 1.1
Pumping of liquids and extraction of leachate in landfill, drainage of fluids contaminated by hydrocarbons and groundwater. The ATEX pumps in conformity with 2014/34/UE Directive can be installed in potentially explosive atmospheres according to the marking explained hereafter.
Price On Request4″ ATEX Pump ID BETA EX 6 kW 1.1
Price On Request -
4″ ATEX Pump ID ALPHA EX 24 kW 2.2
Pumping of liquids and extraction of leachate in landfill, drainage of fluids contaminated by hydrocarbons and groundwater. The ATEX pumps in conformity with 2014/34/UE Directive can be installed in potentially explosive atmospheres according to the marking explained hereafter.
Price On Request4″ ATEX Pump ID ALPHA EX 24 kW 2.2
Price On Request -
4″ ATEX Pump ID ALPHA EX 17 kW 1.5
Pumping of liquids and extraction of leachate in landfill, drainage of fluids contaminated by hydrocarbons and groundwater. The ATEX pumps in conformity with 2014/34/UE Directive can be installed in potentially explosive atmospheres according to the marking explained hereafter.
Price On Request4″ ATEX Pump ID ALPHA EX 17 kW 1.5
Price On Request -
4″ ATEX Pump ID ALPHA EX 13 kW 1.1
Pumping of liquids and extraction of leachate in landfill, drainage of fluids contaminated by hydrocarbons and groundwater. The ATEX pumps in conformity with 2014/34/UE Directive can be installed in potentially explosive atmospheres according to the marking explained hereafter.
Price On Request4″ ATEX Pump ID ALPHA EX 13 kW 1.1
Price On Request -
4″ ATEX Pump ID ALPHA EX 9 kW 0.75
Pumping of liquids and extraction of leachate in landfill, drainage of fluids contaminated by hydrocarbons and groundwater. The ATEX pumps in conformity with 2014/34/UE Directive can be installed in potentially explosive atmospheres according to the marking explained hereafter.
Price On Request4″ ATEX Pump ID ALPHA EX 9 kW 0.75
Price On Request