Electromagnetic Flow Meter RSMAG
Price On Request
- Flow measurement for conductive liquids
- Dn from 25 to 200 mm
- Connections DIN 11851 and CLAMP DIN 32676
- Measurement accuracy: ± 0.2%; ± 0.5%
- PFA coatings
- Power supply 85 ÷ 265Vac; 12Vdc; 24Vdc; 24Vac
- Datalogger on USB pendrive
- Removable O-LED display module
- Remote control via Smartphone
RSmag flowmeters are suitable for applications in the food and pharmaceutical industries. DIN or Clamp ISO 2852 process connections are suitable for applications with milk, beer, or other drinks. Manufactured completely in stainless steel with the option for PFA lining makes RSmag suitable for pharmaceutical application.
Most common communication systems such as Modbus, Hart and by means of an app for Android smartphone via Bluetooth. RSmag has an integrated data logger for the recording of the measurements over time. It consists in a USB pen drive which is inserted behind the removable O-LED display VL701. The recorded data are stored in a TXT file that is compatible with Excel or other equivalent analysis software packages.
Specifications
Flow rate range | RSmag is able to process signals from fluids with flow rates of up to 10m / s in both directions (bidirectional meter). |
---|---|
Range dimension/lining material | PFA DN25 ÷ DN250 |
Sensor pipe material | SS304 |
Housing material | epoxy painted aluminum |
Electrodes material | SS316L – Hastelloy C – Titanium – Tantalum |
Measure range | <0,1m3/h ÷ >600m3/h |
Accuracy | ±0,5% standard; ±0,2% opt |
Repeatability | ±0,1% |
Fluid conductivity | >5μS/cm |
Power supply | 85÷265Vac, 24Vdc, 12Vdc. |
Consumption | 6W, max. 8W. |
Temperature range | Remote version operating temperature: RUBBER -10 ÷ +80°C; PTFE -40 ÷ +150°C Compact version operating temperature: RUBBER -10 ÷ +80°C; PTFE -40 ÷ +100°C Storage temperature: -40÷85°C |
Communication | modbus or Hart (opt.) |
Data Logger | Internal data logger to USB pen drive for flow measurements and analog inputs storing; the measurement storage interval can be set from 15 to 3600 seconds |
Output | 4÷20mA: 0÷500Ω Frequency output: 0,1÷10000 Hz Pulse output: 24Vdc galvanically isolated or open collector galvanically isolated 24V 20mA (opt) Alarm output: 2 relays, 3A 230Vac N.O. |
Input signals | RSmag has 2 active analog inputs at 24Vdc for 2-wire transmitters connection (eg. Temperature or pressure) and 1 digital input for an external contact connection for the integrated batch function restart and for partial totalizer management. |
Reverse Flow | Allows measure and totalization of reverse flow |
Output Testing | Relays output: Transmitter can switch relays at testing value. Current Source: Transmitter can be commanded to supply a specified test current between 4.0 and 20.0 mA. Frequency Source: Transmitter can be commanded to supply a specified test frequency between 1 and 10000 Hz. |
Low Flow Cutoff | Adjustable. Below selected value, instantaneous flow and outputs are driven to the zero flow rate signal level |
Humidity Limits | 0-100% RH to 150 °F (65 °C), non condensing. |
Damping | Adjustable between 1 and 99 seconds |
Compact version IP rating | IP67 |
Remote version IP rating | sensor IP67 / IP68 (by request) – converter IP67 |
Anti-condensation filter | Anti-condensation filter installed on converter |